Improvement #11

A better logging of the notification of AsynchrounsCommandListener

Added by Stefano Lenzi about 8 years ago. Updated almost 8 years ago.

Status:New Start date:09/21/2010
Priority:Normal Due date:
Assignee:Stefano Lenzi % Done:

0%

Category:zigbee.cc2480.datalink Spent time: -
Target version:org.aaloa.zb4osgi.zigbee.cc2480.datalink-1.X
Has a patch:No Has license agreement signed:No

Description

At the moment the HWHighLevelDriver cannot provide any log message for identifying situation like:
  • no listener handled the ZToolPacket
  • multiple listener handled the ZToolPacket
    whch may result very handy for debugging.
It is not possible due to the poor interface of AsynchrounsCommandListener. We propose two approach:
  1. change the return type from void to boolean: so the implementor must to return true if and only if they used the ZToolPacket
  2. create a filter class which may be used by the HWHighLevelDriver to notify only the interested AsynchrounsCommandListener

History

#1 Updated by Stefano Lenzi about 8 years ago

  • Subject changed from A better logging of for the notification of AsynchrounsCommandListener to A better logging of the notification of AsynchrounsCommandListener

#2 Updated by Stefano Lenzi about 8 years ago

  • Target version changed from org.aal-persona.zigbee.cc2480.datalink-0.6.0 to unplanned

It is not a blocking issue so considering that the milestone deadline is elapsed we must move this issue for next release.

#3 Updated by Stefano Lenzi about 8 years ago

  • Target version changed from unplanned to org.aaloa.zb4osgi.zigbee.cc2480.datalink-0.7.0

#4 Updated by Stefano Lenzi almost 8 years ago

  • Target version changed from org.aaloa.zb4osgi.zigbee.cc2480.datalink-0.7.0 to org.aaloa.zb4osgi.zigbee.cc2480.datalink-1.X

Moved to the next release cycle